detail shot sheathing and exterior framing finish weather barrier zip plywood taped in place exterior sheathing 7 16 zip plywood structural sheathing in 4x8 sheets applied with metal fasteners insulation r 21 wall insulation or as required by the building code exterior finish certa plank siding mechanically applied to exterior of building exterior stone fa ade per plan 30 high off sill or deck certainteed stone facade choice of color facia azek or equivalent vinyl vented soffit corner posts 4 vinyl corners mechanically attached white in color unless specified on plans exterior doors exterior door therma true fiberglass front door as per plans self sealing door with sill guard flashing system locksets non mastered schlage brand locksets or equivalent windows and garage doors windows installed per plan black exterior white interior double hung vinyl windows thermopane low e glass argon filled with grilles between glasses as shown on plan garage doors insulated craftsman style doors white insulated garage door openers included see allowances roof construction roofs roof pitch 9 12 pitch or as shown on plans rafter sizes per plan to code ceiling insulation r 49 blown in insulation roof sheathing 1 2 zip sheathing ice guard 25 year weather lock ice and water shield 6 or 2 row s up on the roof all valleys and dormers roofing 30 year architectural fiberglass shingle mechanically attached color green roof vent 10 continuous vent eave and overhangs per drawings ridge vent 25 year roll ridge vent drip edge white galvanized